Skip to Content

AZURA® UVD 2.1L UV/VIS Detector

https://store.knauer.net/web/image/product.template/62910/image_1920?unique=d7aea55

with Test Cell, without Flow Cell, 190-750 nm

The KNAUER AZURA® UVD 2.1L UV/VIS Detector is a competitively priced HPLC spectrophotometer designed for routine HPLC applications, including fast LC methods. It is equipped with a deuterium lamp that covers a wavelength range from 190 to 750 nm. This robust detector not only offers excellent technical specifications but also features a highly flexible and compact design. 

Due to the detector’s smart design, the flow cell is easily accessible and can thus be changed very quickly. Users can choose from a wide range of flow cells with either bio-inert or stainless-steel wetted parts, suitable for both analytical and preparative LC applications, with flow rates ranging from 10 μl/min to 10 l/min. 

The UVD 2.1L can be controlled using ClarityChrom®, OpenLAB®, Chromeleon™, ChromGate® and PurityChrom® software, as well as Mobile Control software for stand-alone operation. Control can be achieved via LAN or through analog input/output, allowing for seamless integration into almost any LC system.


  • Detector Type
  • Detection Channels
  • Wavelength Range
  • Spectral Bandwidth
  • Wavelength Accuracy
  • Wavelength Precision
  • Light Source
  • Baseline Noise Level (Test Cell, 254 nm, ASTM E1657-98)
  • Drift (254 nm, ASTM E1657-98)
  • Linearity (274 nm, ASTM E1657-98)
  • Max. Data Rate
  • Time Constants
  • Integration Time
  • Leak Sensor
  • Flow Cell
  • GLP Report
  • GLP Report
  • GLP Report
  • GLP Report
  • Display
  • Interfaces
  • Interfaces
  • Interfaces
  • Interfaces
  • Control
  • Control
  • Control
  • Control
  • Inputs
  • Inputs
  • Inputs
  • Inputs
  • Analog Inputs
  • Outputs
  • Outputs
  • Outputs
  • Analog Outputs
  • Ambient Conditions
  • Power Supply
  • Dimensions (W x D)/ (W x H x D)
  • Weight

This combination does not exist.

Terms and Conditions
Images may differ from the actual product.


Internal Reference: ADA01XA

Technical Data

General
Detector Type Variable single wavelength UV detector
Detection Channels 1
Wavelength Range 190-750 nm
Light Source Deuterium (D₂) lamp with integrated GLP chip
Flow Cell Not included
Display Mobile Control (optional)
Specifications
Wavelength Accuracy ± 2.5 nm
Wavelength Precision 0.3 nm (ASTM E275-93)
Features
Leak Sensor Yes
GLP Report Lamp recognition, Operating hours, Light source operating hours, Number of lamp ignitions
Specification - Detection
Spectral Bandwidth 11 nm at Hα line (FWHM)
Baseline Noise Level (Test Cell, 254 nm, ASTM E1657-98) ± 15 µAU
Drift (254 nm, ASTM E1657-98) 300 µAU/h
Linearity (274 nm, ASTM E1657-98) > 2.0 AU
Max. Data Rate 50 Hz (LAN) / 20 Hz (analog)
Time Constants 0.1 / 0.2 / 0.5 / 1.0 / 2.0 / 5.0 / 10.0 s
Integration Time Automatic
Your Dynamic Snippet will be displayed here... This message is displayed because you did not provided both a filter and a template to use.
Download KNAUER Product Selection Guide

Find product specifications here

Instruments, components and services for (U)HPLC, Prep-LC, FPLC and Osmometry.

Download KNAUER Manuals