KNAUER AZURA HPLC 862 bar system with isocratic pump, RID and backflush valve for ASTM D6591/IP391/EN 12916

https://store.knauer.net/web/image/product.template/88204/image_1920?unique=cf6a9e3

Included system components: Eluent tray E 2.1L, Pump P 6.1L isocratic, Autosampler AS 6.1L, Column thermostat CT 2.1, Refractive index detector RID 2.1L, Backflushing valve V4.1 with valve drive VU 4.1, ClarityChrom Software, Accessories and tools

Cost-effective isocratic solution. Ideally suited for training and quality control. Suitable for EN12916 (IP391/07)

Eluent delivery
The  Pump P6.1L with a HPG configuration features a solvent selection valve to set up to 4 solvents to the system of which two can be blended simultaneously. The internal degassing unit will prevent air bubbles in the system. Every P 6.1L comes with an attached mixing chamber, which can be changed to a larger volume depending on the applications needs.  

Sample Injection
The Autosampler AS 6.1L can inject 0.1 – 5000 µl to have a large flexibility. Using standard vials or two microtiter plates will give you a maximum sample capacity of up to 768 samples or 108 vials.

Column thermostating
The Column thermostat CT 2.1 is suitable for column thermostatization above and below room temperature. The instrument operates with a microprocessor controlled Peltier element for exact temperature settings.

Chromatography data system
KNAUER ClarityChrom® is a powerful, yet easy-to-use chromatography software for instrument control, data acquisition and data processing. It is an economical solution compared to other more complex chromatography software while still offering FDA 21 CFR Part 11 compliance.

Detection
The detector  AZURA RID 2.1L offers a wide linear dynamic range, a low internal volume of 43 µl and a maximum flow rate of 10 ml/min. The intelligently designed optical unit with advanced temperature control ensures high sensitivity, fast baseline stabilization, and excellent reproducibility.   

29,990.00 € 29990.0 EUR 29,990.00 € VAT Excluded

29,990.00 € VAT Excluded

  • Eluent delivery
  • Sample Injection
  • Detection
  • Chromatography Software CDS
  • Column Tempering

This combination does not exist.

Terms and Conditions
Images may differ from the actual product.


Internal Reference: 986 701 200

Technical Data

Eluent delivery P 6.1L 862 bar isocratic
Sample Injection AS 6.1L
Detection RID 2.1L
Chromatography Software CDS ClarityChrom
Column Tempering Column Thermostat CT 2.1